Egress windows for manufactured homes jan.
Roof load zone map.
Where flat roof snow loads exceed 30 psf 1 44 kn m 2 20.
I guess the cfr regulations were difficult to discern because of many revisions and ammendments.
The locations of wind load zones are shown in the figures 1611 1a 1611 1b 1611 1c maps.
The hud code stipulates at 3280 305 c 3 that the home shall be designed and constructed to conform to one of three roof load zones.
Round footing sizing table.
This zone accounts for about 5 of the roof surface represented the corners of the roof.
Any areas between the wall corners that are not included within zone 5.
Where flat roof snow loads exceed 30 psf 1 44 kn m 2 20 percent shall be combined with seismic loads.
Roof load zones vary depending on snow levels in different parts of the u s.
Roof load zone map each manufactured home must be designed according to the federal manufactured home construction and safety standards at 24 cfr 3280 commonly called the hud code.
10 percent of least horizontal dimension or 0 4h whichever is smaller.
Zone 2 consists of the county of worcester.
Used for roof overhang area along the perimeter of zone 3.
Box 441022 moscow id 83844 1022.
Crane hook loads need not be combined with roof live load or with more than three fourths of the snow load or one half of the wind load.
Zone 1 consists of the counties of berkshire franklin hampshire and hampden.
780 cmr 1611 0 wind load 1611 1 wind load zones.
Sheikh taheri published by the ui department of civil engineering 1986.
Snow load map ground load and roof load map per minnesota rules 1303 1700.
Flat roof snow loads of 30 psf 1 44 kn m 2 or less need not be combined with seismic loads.
The hud roof load zone map was produced because of this confusion but did not change the map that cfr already used.
Crane hook loads need not be combined with roof live load or with more than three fourths of the snow load or one half of the wind load.
Has the highest load.
Square footing sizing table.
Frost depth map minnesota rules 1303 1600.
A publication can be purchased called ground and roof snow loads for idaho by r.
To request a copy send a check for 22 50 includes postage payable to department of civil engineering university of idaho p o.
I believe the current hud roof load map was established in 1974 but the map was based on the existing cfr code of federal regulations.
And zone 3 consists of the counties of essex middlesex suffolk norfolk plymouth.
For example states like alaska and maine have some of the highest snow load requirements.
2 the basic roof snow load factor c b shall be 0 8 except that for large roofs it shall be a 1 0 30 l c 2 for roofs with c w 1 0 and l c greater than or equal to 70 m or b 1 3 140 l c 2 for roofs with c w 0 75 or 0 5 and l c greater than or equal to 200 m where l c characteristic length of the upper or lower roof defined as 2w w l in metres.